Owner`s manual
The Problem Solver
I,lin e ICe,serve
Questions ?
Use this
prob&m
solver/
PROBLEM
APPLIANCE
DOES NOT OPERATE
VIBRATION OR
RATTLING (Slight
vibration is normal.)
COMPRESSOR
MOTOR OPERATES
FOR LONG PERIODS
OR CYCLES ON AND
OFF FREQUENTLY
COMPARTMENT
TOO WARM
APPLIANCE
HAS ODOR
DOOR NOT
CLOSING
PROPERLY
MOISTURE FORMS
ON OUTSIDE OF
APPLIANCE
FROST OR MOISTURE
COLLECTS INSIDE
INTERIOR LIGHT
DOES NOT WORK
POSSIBLE CAUSE
• Appliance is so quiet that most of the time w)u will hear low or no
operating noise.
• Appliance may be in defl'ost cycle when compressor motor does not
operate fi)r up to 2 hours.
• If interior light is not on, appliance mav not be plugged in at
wall outlet. Push the plug completely into the wall outlet.
• The fllse is blown/circuit breaker is tripped. Replace fllse or reset
the breaker.
• At!just the lexeling legs as shown in the Installation Instructions.
• Normal when appliance is fi_t plugged in. Wait 24 hours fin" the
appliance to completely cool down.
• Often occtu_ when large amounts of beverages are placed in appliance.
This is nom_al.
• Door leti open or package holding door open.
• Hot weather or fl'equent door openings. This is nom_al.
• Temperature control set at the coldest setting.
See Temperature Control. Allow 24 hours tot temperature to change.
• Temperature control not set cold enough.
See Temperature Control. Allow 24 hours tot temperature to change.
• Warm weather or fl'equent door openings.
• Door lett open tor long time.
• Package may be holding door open.
• Interior needs cleaning. See Care and Clealfing.
• Kee I) open box of baking soda in appliai_ce; replace evelw 3 n_onths.
• Door gasket is sticking or tolding ove_: Apply petroleum ,jelly
or parattin wax to the tace of the gasket.
• The door is hitting an internal component inside the appliance.
Adilist interior components to prevent interference.
• Not unustlal during periods of high humidim If bothersome,
wipe surtace chT; otherwise, moisture will evaporate in time.
• Door leti open or package holding door open.
• Too fl'equent or too long door openings.
• In humid weather, air carries moisture into appliance when door
is opened. Unit will dissipate moisture in time. If bothersome,
wipe surtace dry.
• Temperature control set at coldest setting.
• No power at outlet.
• I,ight bulb needs replacing. See Care and Cleaning.
15