Specifications

Desi n Guide
THE INSTALLATION SPACE
34-I/2"-35"
/
"23-3/4" Min. Standard
*'24-1/4" Min. StainlessSteelFlush
**'24-3/4" Min. FramedFlush
NOTE:
Handle and handle
standoff depth is 1-3/4"
*For a standard installation of Custom-Framed unit: The
product must beinstalled so that the front face will project 2"
forward of adjacent cabinets.Thisposition will allow a full door
swing and prevent interference with adjacent cabinetry. The
opening between cabinets must be 23-3/4" minimum.
*For a standard installation of Stainless Steel unit: The product
must be installed so that the front face will project 1-3/4"
forward of adjacent cabinets.Thisposition will allow a full door
swing and prevent interference with adjacent cabinetrg.The
opening between cabinets must be 23-3/4" minimum.
**For a flush installation of Stainless Steel unit: Install a
1/2"-wide filler strip on the hinge side.Thefiller strip will act as
a spacer between the door caseand adjacent cabinets and will
prevent interference with the cabinet door swing.Recessthe
filler strip 2" back from the front face of the unit, or even with
the front edge of the product case(behindthe gasket).Thewidth
of the opening must be 24-1/4" (includingthe 1/2" filler strip).
***For a flush installation of Custom-Framed unit: Install a
1"-wide filler strip on the hingeside.The filler strip will act as
a spacer between the door caseand adjacent cabinets and
will prevent interference with the cabinet door swing. Recess
the filler strip 2" backfrom the front face of the unit, or even with
the front edge of the product case(behindthe gasket).Thewidth
of the opening must be 24-3/4" (includingthe 1" filler strip).
The wine chiller, wine reserve and beverage center can
be installed freestanding.
Additional Specifications
A 120volt 60Hz.,15 or 20amp power supplg is required.
An individual properlg grounded branch circuit or circuit
breaker is recommended.Install a properlg grounded
3-prong electrical receptacle recessed into the back wall
as shown. Electricalmust be located on rear wall as shown.
NOTE:GFI(groundfault interrupter)is not recommended.
THE INSTALLATION SPACE (cont.)
_ CABINET
............................................................................................
Installation Dim.A /
]
Filler panel or cleat
to be set back even
with front of case.
Front edge of product case
I
Frontface *
These products will fit flush to \
adjacent cabinets when installed
with a Dim. A-width filler panel
or cleat. Thefiller panel should
be recessed or set back behind
the door and even with the front
edge of the product case.
CABINET
Product Dim:A
ZDWI240, ZDBI240 1"
ZDWC240, ZDWR240 1/2"
ZDBC240, ZDBR240 1/2"
CABINET
Y
Dim.A
A
Standard
Installation
Frontedgeof productcase
Front face
In a standard installation, '\_ °°
the product will project forward
of adjacent cabinets. See Dim. A.
PrOduct Dim:A
ZDWI240, ZDBI240 2"
ZDWC240, ZDWR240 1-3/4"
ZDBC240, ZDBR240 1-3/4"
CABINET