Quick Specs
ZDP486NRNSS (NATURAL GAS)MONOGRAM 48" DUAL-FUEL PROFESSIONAL
RANGE WITH 6 BURNERS AND GRILL
DIMENSIONS AND INSTALLATION INFORMATION
(IN INCHES)
Product Specification Created 8/19
ELECTRICAL REQUIREMENTS
Ranges must be supplied with 208/240V, 60Hz, and
connected to an individual, properly grounded branch
circuit protected by a circuit breaker or time-delay fuse.
Install a 50-amp circuit for 48" ranges. The receptacle
must be a NEMA 14-50R device to accept the four-prong
plug on the range.
OPTIONAL BACKSPLASH ACCESSORIES
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessory is available, or a custom, non-
combustible backsplash can be used
ORDER ONE WITH A 48"-WIDE RANGE BACKSPLASH
UXADJB48PSS– 30"-36" adjustable-height
backsplash with warming shelf
SIDE VIEW WITH A BACKSPLASH
Locate gas and electric as shown
GAS SUPPLY
• The natural gas models are designed to operate at
5" water column pressure. For proper operation, the
pressure of the natural gas supplied to the regulator
must be between 7" and 13" water column.
• The LP models are designed to operate at 10" water
column pressure. For proper operation, the pressure
of the LP gas supplied to the regulator must be
between 11" and 13" water column.
UTILITY LOCATIONS
8"
14" 16"
48"
6-1/2"
2"
2"
6-1/2"
Gas/
Electric
Electric
10-1/2"
1"
12"
28-1/4" to
Beveled
Edge of Control
Panel Bullnose
27-1/2" to
Beveled Edge
- Maximum
Adjacent
Cabinet
Depth for
Flush
Installation
13/16"
30-36"
3-3/16"
Control Panel
Depth
28-1/4"
to Front of
Door
48-1/4"
with Oven Door
Open
30-7/8"
to Front of
Handle
35-1/4"
to
36-3/4"
7" Control
Panel Height
Countertop level
28-7/8"
to Front
Edge
Optional
Backsplash
Accessories
12" min. to combustibles or 0" to
a non-combustible material above
the cooking surface
0" clearance
to a back or
side wall below
the cooking
surface