Specification Sheet
PAGE 4 OF 4
For questions about your 
appliance, please call 1-800-626-2000.
Product Specication Revised 1/21
GAS PRESSURE REGULATOR 
You must use the gas pressure regulator supplied with this 
rangetop. For proper operations the inlet pressure to the 
regulator should be as follows:
Natural Gas:
Minimum pressure: 6" of Water Column 
Maximum pressure: 13" of Water Column
Propane (LP) Gas:
Minimum pressure: 11" of Water Column 
Maximum pressure: 13" of Water Column
See installation instructions for more details
OPTIONAL BACKSPLASH ACCESSORIES 
• e range requires a 12" minimum clearance to a vertical 
combustible surface at the rear. A backsplash is required 
for installations with less than 12" clearance. e following 
backsplash accessories are available, or a custom, non- 
combustible backsplash can be used.
• Order one with a 36"-wide range backsplash:
• UX12BS48PSS–12"-height backsplash
• UXADBS48PSS–30"-36" adjustable-height backsplash 
with warming shelf
12" min. to combustibles or 0" to
a non-combustible material above
the cooking surface
0" clearance
to a back or
side wall below
the cooking
surface
HELPFUL TIPSDIMENSIONS AND INSTALLATION  
INFORMATION (IN INCHES)
8"
11" 21"
48"
6-1/2"
2"
Gas/
Electric
3"
Utility Locations
UTILITY LOCATIONS
Locate gas and electric as shown