Quick Specification
PAGE 3 OF 4
For questions about your 
appliance, please call 1-800-626-2000.
Product Specication Revised 3/22
All Dual-Fuel Professional Ranges are factory set for natural gas.
NOTE 
A propane conversion kit is included with the range. High 
Altitude kit for operation above 6,000 feet (for Natural 
and LP gas models), is available at an additional cost. The 
conversion must be performed by a qualied gas installer at 
additional cost.
HA NG Service Kit: WB28X39726 
HA LP Service Kit: WB28X39727
INSTALLATION INFORMATION 
Before installing, consult installation instructions packed with 
product or online at Monogram.com for current dimensional 
data. A suitable overhead vent hood is required for models 
with a grill and is recommended for all other models.
ADVANCE PLANNING 
Refer to dimensional drawings for appropriate placement 
and necessary clearances when planning the installation.
• Working areas adjacent to the range should have 
18" minimum clearance between countertop and 
cabinet bottom.
• Clearance between range and side wall or combustible 
material must be at least 12" on each side.
• Installation must conform with local codes. In the absence 
of local codes, the range must comply with the National 
Fuel Gas Code, ANSI Z223.1-1990.
HELPFUL TIPSDIMENSIONS AND INSTALLATION  
INFORMATION (IN INCHES)
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and 
the bottom of the wall cabinet.
Non-Combustible
Material**
16"
Max.
18"
Min.
48" Min.
12" Minimum
Each Side
12" Minimum
to Adjacent Wall
**As defined in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials
are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less
than 12” must be approved by local codes
and/or the authority having jurisdiction.
 WARNING
A suitable overhead vent hood is required. A custom hood 
installation with exposed horizontal combustible surfaces 
must have an Auto-On feature. Refer to hood installation 
instructions for specic hood clearances.
The surface of the entire back wall above the range and 
below the hood must be covered with a non-combustible 
material such as metal, ceramic tile, brick, marble or other stone.
** As dened in the National Fuel Gas Code (ANSI Z223.1/CSA 
B149.1, Current Edition). Clearances from non-combustible 
materials are not part of the ANSI Z21.1/CSA 1.1 scope and  
are not certied by CSA. Clearances less than 12” must 
be approved by local codes and/or the authority having 
jurisdiction.