Specification Sheet

PAGE 4 OF 4
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Revised 3/21
GAS PRESSURE REGULATOR
You must use the gas pressure regulator supplied with this
rangetop. For proper operations the inlet pressure to the
regulator should be as follows:
Natural Gas:
Minimum pressure: 6" of Water Column
Maximum pressure: 13" of Water Column
Propane (LP) Gas:
Minimum pressure: 11" of Water Column
Maximum pressure: 13" of Water Column
See installation instructions for more details
OPTIONAL BACKSPLASH ACCESSORIES
The range requires a 12" minimum clearance to a
vertical combustible surface at the rear. A backsplash is
required for installations with less than 12" clearance. The
following backsplash accessories are available, or a custom,
non- combustible backsplash can be used.
• Order one with a 36"-wide range backsplash:
• UX12BS48PSS–12"-height backsplash
UXADBS48PSS–30"-36" adjustable-height backsplash
with warming shelf
OPTIONAL STAINLESS STEEL KNOB KITS
AVAILABLE
ZXPR36KKTSS - 30" and 36" Range
ZXPR48KKTSS - 48" Range
12" min. to combustibles or 0" to
a non-combustible material above
the cooking surface
0" clearance
to a back or
side wall below
the cooking
surface
HELPFUL TIPSDIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
8"
11" 21"
48"
6-1/2"
2"
Gas/
Electric
3"
Utility Locations
UTILITY LOCATIONS
Locate gas and electric as shown