Quick Specs
ZDP364NDNSS (NATURAL GAS)MONOGRAM 36" DUAL-FUEL PROFESSIONAL 
RANGE WITH 4 BURNERS AND GRIDDLE
DIMENSIONS AND INSTALLATION INFORMATION 
(IN INCHES) 
Product Specification Created 8/19
Professional ranges oer a number of choices in size and 
cooktop configurations.
All Dual-Fuel Professional Ranges are factory set for 
natural gas.
NOTE 
A propane conversion kit is included with the range. High 
Altitude kit, WB28K10553 for operation above 6,000 feet 
(for Natural and LP gas models), is also available. The 
kits must be installed by a qualified service technician at 
additional cost.
INSTALLATION INFORMATION
Before installing, consult installation instructions packed 
with product or online at Monogram.com for current 
dimensional data. A suitable overhead vent hood is 
required for models with a grill and is recommended 
for all other models.
ADVANCE PLANNING
Refer to dimensional drawings for appropriate placement 
and necessary clearances when planning the installation.
• Working areas adjacent to the range should have 
18" minimum clearance between countertop and 
cabinet bottom.
• Clearance between range and side wall or combustible 
material must be at least 12" on each side.
• Installation must conform with local codes. In the 
absence of local codes, the range must comply with 
the National Fuel Gas Code, ANSI Z223.1-1990.
 WARNING
Installations without a hood require 48" minimum 
to combustibles. A custom hood installation with 
exposed horizontal combustible surfaces must 
have an Auto-On feature. Refer to hood installation 
instructions for specific hood clearances.
The surface of the entire back wall above the range 
and below the hood must be covered with a non-
combustible material such as metal, ceramic tile, 
brick, marble or other stone.
35 7/8" width
28 1/4"
35 1/4"
to
36 3/4"
height
3 1/4"
to 4 3/4"
Toekick/leg
height
Depth
to front
of door
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall
on each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and 
the bottom of the wall cabinet.
Non-Combustible
Material
13"
max.
18"
min.
36" min.
48" minimum
to combustibles
12" minimum
each side
12" minimum
to adjacent wall