Specification Sheet
PAGE 4 OF 4
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Revised 12/20
BACKSPLASH
e range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required for
installations with less than 12" clearance. A custom, non-
combustible backsplash can be used.
GAS PRESSURE REGULATOR
You must use the gas pressure regulator supplied with this
rangetop. For proper operations the inlet pressure to the
regulator should be as follows:
Natural Gas:
Minimum pressure: 6" of Water Column
Maximum pressure: 13" of Water Column
Propane (LP) Gas:
Minimum pressure: 11" of Water Column
Maximum pressure: 13" of Water Column
See installation instructions for more details
UTILITY LOCATIONS
12" min. to combustibles or 0" to
a non-combustible material above
the cooking surface
0" clearance
to a back or
side wall below
the cooking
surface
4-5/8"
9-3/8"11-3/8"
2"
30"
3"
Utility Locations
6"
Gas/
Electric
HELPFUL TIPSDIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
Locate gas and electric as shown