PROBLEM POSSIBLE CAUSE
INTERIOR LIGHT 
DOES NOT WORK
• No power at outlet.
• Light bulb needs replacing. See Care and Cleaning.
• Controls are set to OFF. Press ON/OFF pad on control panel.
• The Sabbath Mode may be operating. Turn off Sabbath Mode.
HOT AIR FROM 
BOTTOM OF 
APPLIANCE
• Normal air flow cools the motor. In the refrigeration process, it 
is normal that heat be expelled in the area under the appliance. 
Some floor coverings are sensitive and will even discolor at these 
safe and normal temperatures.
APPLIANCE NEVER 
SHUTS OFF BUT 
TEMPERATURES 
ARE OK
• Adaptive defrost keeps compressor running during door openings. 
This is normal. The appliance will cycle off after the door remains 
closed for two hours.
• Normal operation in extreme temperatures.
ACTUAL 
TEMPERATURE 
NOT EQUAL TO SET 
TEMPERATURE
• Unit just plugged in. Allow 24 hours for the system to stabilize.
• Door open for too long. Allow 24 hours for the system to stabilize.
• Warm contents added to appliance. Allow 24 hours for the system
• Defrost cycle is in process. Allow 24 hours for the system to 
stabilize.
7KHUPLVWRUPD\EHEORFNHGZKLFKFDQDႇHFWWKHRYHUDOO
temperature. The thermistor is located on the right hand side just 
above the third shelf.
TEMPERATURE 
WILL NOT ADJUST
• Temperature may be in lockout mode. Press both + and – pads for 
5 seconds to unlock the temperature.
• Thermistor may be blocked, which can affect the overall 
temperature. The thermistor is located on the right-hand side, just 
above the third shelf.