Installation Guide
31-1000645
5
THE INSTALLATION SPACE
Choose the location:
• This product has been designed as a free-standing unit;
however, if desired, it may also be built-in.
• These products may be closed in on the top and
three sides as long as the front is unobstructed for air
circulation and proper access to the door.
• Do not operate these products where the temperature
will go below 45°F (7°C) or above 120°F (49°C).
• Unit must be installed on a structurally sound and
level surface strong enough to support a fully loaded
refrigerator, or approx. 250 lbs.
7KHFXWRXWGHSWKVKRXOGEHƎ
The cutout dimensions shown allow for a full door
swing and access to the pull-out racks when installed in
VWDQGDUGƎGHHSFDELQHWV
• The Outdoor/Indoor Refrigerator can be used free-
standing.
,ILQVWDOOLQJEHWZHHQIUDPHOHVVFDELQHWVDƎZLGH¿OOHU
strip or side panel may be required on the hinge side.
7KH¿OOHUVWULSZLOODFWDVDVSDFHUEHWZHHQWKHFDVHDQG
adjacent cabinet door swing. The width of the opening
PXVWLQFOXGHWKH¿OOHUSDQHOV
NOTE:,QDVWDQGDUGƎRSHQLQJWKHGRRUZLOOSURWUXGH
ƎIRUZDUGRIWKHVXUURXQGLQJFDELQHWV
$GGLWLRQDO6SHFL¿FDWLRQV
• A 120 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall as
shown. Electrical must be located on rear wall as shown.
• THIS PRODUCT MUST BE CONNECTED TO A
POWER SOURCE WITH GROUND FAULT CIRCUIT
INTERRUPTER (GFCI) PROTECTION WHEN
INSTALLED IN AN OUTDOOR LOCATION. LOCAL
CODES MAY REQUIRE A SEPARATE CIRCUIT.
Design Guide
Free-Standing – Use
canopy top
Built-In – Remove
canopy top (if needed)
F
D
E
B,C
S
H
G,I
D
F
E
A
H
B,C
G,I
NOTE:
+DQGOHDQGKDQGOHVWDQGRႇGHSWKLVƎ
(Actual handle may vary slightly.)
Description
Outdoor
ZDOD240
Dimensions
A Height (Level leg down) includes hinge 34-3/16” (868.4 mm)
B Width (Including door) 23-5/8” (599 mm)
C Width without door 23-7/16” (596 mm)
D
Handle Depth Range unless Custom
Handle
2-1/8”, 2-5/8”
(54, 66.7 mm)
E
Depth including Door (& custom panels)
without Handle
23-3/4” (601.7 mm)
F Depth without door 21-13/16” (554.4 mm)
G Toe Kick Height (floor to bottom of door) 4”
H Level Leg Max Adjustment 1”
I
Decorative Toe Kick Part Dimension 23-7/16” W x 3-1/8” H
(596 W x 79 H mm)
J
Standard Cabinet Opening Single Width
FLUSH
24”
K Minimum Cabinet Opening Single Width 23-3/4”
L
Minimum Cabinet Opening Side by Side
Width
Not Applicable
M
Standard Cabinet Opening Side by Side
Width FLUSH
Not Applicable
N Maximum Cabinet Opening Height 35”
O Minimum Cabinet Opening Height 34.5”
P Standard Cabinet Opening Depth 24”
Q Gap between drawers Not Applicable
R
Depth with door open 90 or drawer fully
open
45-9/16”
(1157 mm)
S Height with top cover (Level leg down) 35-7/8” (911.4 mm)
Locate
Outlet
1-1/2"
P
9" Max.
10-1/2"
N,O
K
Min. Cabinet Opening
Std. Cabinet Opening
J
FOR MODELS ZDOD240