Specifications
ZDBR240HBSMONOGRAM BEVERAGE CENTER
Product Specification Revised 1/18
INSTALLATION
Installation Space
This module can be installed
beneath a countertop or can
be used free-standing.
For a standard installation
of Stainless Steel unit: The
product must be installed so
that the front face will project
1-3/4" forward of adjacent
cabinets.
For a flush installation of
Stainless Steel unit: Install a
1/2" wide filler strip on the
hinge side. The width of the
opening must be 24-1/4" wide.
Location Requirements
All Monogram Refrigeration
Modules may be closed in on
the top and sides as long as
the front is unobstructed for
air circulation and door swing.
• Do not install these products
where the temperatures will
go below 55°F (13°C) or
above 90°F (32°C).
• Do not install where they will
be subject to direct sunlight,
heat or moisture.
• These products are not
designed to be stacked one
over the other.
Side-by-Side Installation
For a complete refreshment
center, install a Monogram
Wine Reserve and Beverage
Center together.
• Products must operate from
separate properly grounded
receptacles.
See Installation Instructions
for side-by-side information.
34 1/2"
(87.6)
Min
underside of
counter to floor
35" (88.9) Max
24"
(61.0)
min cutout depth
CUTOUT INSTALLATION
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
10 1/2" (26.7)
1 1/2" (3.8)
24 1/4" (61.6) Min
Flush Inset
9" (22.9)
Max
ELECTRIC
23 3/4" (60.3) Min
cutout width
ZDBC240NBS
34 1/2"
(87.6)
Min
underside of
counter to floor
35" (88.9) Max
24"
(61.0)
min cutout depth
CUTOUT INSTALLATION
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
10 1/2" (26.7)
1 1/2" (3.8)
24 1/4" (61.6) Min
Flush Inset
9" (22.9)
Max
ELECTRIC
23 3/4" (60.3) Min
cutout width
ZDBC240NBS
NOTES
PRODUCT DIM. A
ZDWI240, ZDB1240 1"
ZDWR240, ZDBR240 1"
ZIB1240, ZIF1240 1"
ZIFS240, ZIBS240 1/4"
ZDOD240 1-1/4"
PRODUCT DIM. A
ZDWI240, ZDB1240 2"
ZDWR240, ZDBR240 1-3/4"
ZIFS240, ZIF1240 1-5/8"
ZDOD240 1-7/8"
ZIB1240, ZIBS240 2-5/8"
CABINET CABINET
Dim. A
Front Edge of
Product Case
Front Face
Standard
Installation
110º
120º
In a standard installation, the
product will project forward of
adjacent cabinets. See Dim. A.
23 3/4" min.
CABINET CABINET
These products will fit flush to adjacent
cabinets when installed with a Dim. A - width
filler panel or cleat. The filler panel should be
recessed or set back behind the door and
even with the front edge of the product case.
110º
120º
Flush
Installation
Filler panel or cleat to be set
back even with front of case.
Front Edge of
Product Case
Dim. A
Front Face
24 1/4" min. width
stainless steel models
REFRIGERATION MODULES, TOP VIEW