Installation Instructions
7
STEP 3 LEVEL
• Use an adjustable wrench to turn the leveling legs and
raise or lower the product.
• Adjust carefully; the product should be level and plumb
with cabinetry, and should align with adjacent toekick
height.
STEP 5 SLIDE PRODUCT INTO
THE CUTOUT
• Carefully, slide the unit into the opening. Be careful not
to entangle the power cord.
• Make certain that the door protrudes 1s beyond the
surrounding cabinets (1-7/8s for custom frame models).
• Check again to be sure the unit is level.
STEP 4 CONNECT POWER
• Connect power cord plug to a properly grounded
receptacle.
• Check to make sure power is on by opening the door to
see if interior light turns on.
STEP 6 SET TEMPERATURE CONTROLS
• The temperature controls are preset. Refer to the Own-
er’s Manual for more information. Allow 24 hours for
temperature to stabilize.
Turn Right to Lower
Turn Left to Raise
If you skipped Step 2:
• Select the hinge cover marked “R” or “L”, depending on
door swing.
3HHOEDFNLQJRȺWKHWDSHLQVLGHWKHGHFRUDWLYHKLQJH
cover. Press and snap into position.
• Snap the screw hole cover into place on the opposite
side.
Installation Instructions
CUSTOM FRAME PANEL MODELS
Model ZDWI240WII and ZDBI240WII
These models require a custom panel frame surrounding
the glass. There are two options: the panel may be 29-3/4s or
30s high. A 30s panel requires a notch cut into the bottom
of the panel to avoid interference with the hinges.
• Rout the back side of the panel to the dimensions shown.
• A custom handle of your choice or ZTBSS1 Tubular Handle
must be installed before the panel is mounted onto
the door.
NOTE: A solid panel that covers the door glass CANNOT be
installed on these models.
Install the custom panel:
• Open the door fully.
• Remove the gasket surrounding the inside of the door to ex-
pose the existing screw holes for the custom panel.
• Hold the custom frame panel against the door and align care-
fully, top to bottom and side to side. Mark screw hole
locations on the back side of the panel.
• Drill pilot holes in the back side of the custom panel. In hard-
wood, drill 3/32s pilot holes. In softwood, drill 5/64s holes.
• Secure the prepared panel to the door using ten (10)
#8 x 5/8sscrews. Drive the screws through the door frame
and into the wood.
• Replace the gasket.
Choose Option 1 or Option 2 panel size depending on cabinetry
size or style.
23-1/8”
30”
GLASS
25-1/4”
18-5/8”
2-1/4”
Rout the back
side of the
opening 7/16”
deep, 1-1/8” wide
Cut the notch
1/8” deep, 1/4”
wide and 1/4”
high
2-1/4”
1/8”
1/4”
1/4”
2-1/4”
2-1/2” at
bottom
23-1/8”
29-3/4”
GLASS
25-1/4”
3/4” Thick Custom Panel,
Back Side
18-5/8”
2-1/4”
wide,
all sides
Rout the
back side
of the
opening
7/16”deep,
1-1/8” wide
#8 x 5/8"
Screws
GLASS
Back
Custom
Framed
Panel
Door
Frame