Installation Guide
31-1000416 Rev. 0
25
Design Guide - Stainless Steel Installation
36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
23-5/8"
Case Depth
Depth Including Handles:
28-1/16" Minimalist Style Models
28-1/2" Statement Style Models
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24” (60.96 cm)
Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24” (60.96 cm) installation depth shown.
The top case trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
• Water line can enter the opening through the floor or
back wall. The water line should be 1/4” O.D. copper
tubing or QuickConnect
™
kit between the cold water
line and water connection location, long enough to
extend to the front of the unit. Installation of an easily
accessible shut-off valve in the water line is required.
DIMENSIONS AND CLEARANCES
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 84-1/2” (214.63 cm)
max. height. Note that
the top case trim at the
front is 1/2” (1.27 cm)
higher and will overlap
upper cabinetry or soffit.
Use leveling legs and
wheels for a maximum
1” (2.54 cm) height
adjustment.
Product Clearances
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings
between 90° and 130°.
130° Door Swing
90° Door Swing
36-1/2"
90º Door Swing
23-5/8
"
Behind
Frame
4-9/16
" Min. Distance to Wall
90°
130° Door Swing
130°
22-3/4
"
Minimum
to Wall
Allow 22-3/4” (57.8 cm) minimum clearance for a full
130° door swing. Allow 15” (38.0 cm) for pan removal.
For a 90° door swing, allow 4-9/16” (11.81 cm)
minimum clearance to a wall for framed and stainless
steel models. If the 90° doorstop position is used, pan
access is maintained but pan removal is restricted.
See illustration on page 28 to determine door swing
interaction with adjacent cabinets or countertops.
115° Door Swing
16" Min.
to Wall
115°