Installation Instructions
CertainTeed Vinyl Siding Installation Guide
30
Steel framing
When installing CertaWrap Weather-Resistant Barrier over steel 
framing, use screws with minimum 1" diameter washers every 
32" vertically and horizontally. 
STUDfinder
™
 installation instructions
1.   The STUDfinder Installation System combines precisely 
engineered fastening locations with graphics that help ensure 
quick, accurate, and secure installation. Install CertaWrap 
horizontally to exterior walls prior to the application of exterior 
cladding. Vertically position the CertaWrap roll at the corner of 
the structure with the printed side out.
2.   Locate the first stud and verify that it is plumb. Align the first 
stud with the nearest vertical STUDfinder line, allowing for a 
minimum 12" flap to wrap the corner for attachment to the 
adjoining wall. Extend the bottom edge of the CertaWrap 
2"–4" over the sill plate. Apply plastic-capped staples or 
plastic-capped nails every 32" vertically along the first stud 
to secure the Weather-Resistant Barrier into position.
3.  Unroll the CertaWrap along the exterior wall. Wrap CertaWrap 
completely around the building, covering window and door 
openings, plates, sills and corners.
4.  To secure the Weather-Resistant Barrier, use the fasteners 
and fastening schedule that is appropriate for your application. 
The STUDfinder marks will quickly guide you to your desired 
fastening location without the need for chalk lines. Each letter 
is spaced 1.6" apart, and each series spans 16". To achieve 
32" spacing between fasteners, first locate the letter that the 
first row of fasteners covers. The second repeat of that letter 
is at 32".
5.  Pull the CertaWrap snug and fasten it to the studs or sheathing 
and to the top and bottom plates.
6.  When starting a new roll in the middle of a wall, overlap vertical 
and horizontal laps in the field a minimum of 6". When starting 
a new roll at an inside or outside corner, overlap vertical and 
horizontal seams a minimum of 12". All vertical and horizontal 
seams are to be installed in a weatherboard fashion. Lap 
CertaWrap over all existing flashings (e.g. z-flashing, roof-to-
wall flashing, drip cap).
7.  Flash or tape all vertical and horizontal seams and penetrations.
12" 
(min.) 
flap