Installation Instruction
6
31-46542-4
Design Guide
Water and Electrical Locations 
Electrical and water supply should be located in shaded area only as shown.
WARNING
 Connect to potable water supply only.
PREPARING INSTALL WATER LINE
•  A cold water supply is required for automatic icemaker operation. The 
water pressure must be between 40 and 120 p.s.i. (275-827 kPa).
•  Route 1/4” OD copper or SmartConnect
™
 plastic tubing between the 
house cold water line and the water connection location.
•  Tubing should be long enough to extend to the front of the encloasure. 
•  Water line can enter an opening through the floor or back wall. 
• Install a shut-off valve between the icemaker water valve and cold water 
supply in the home. 
NOTE: 
•  It is recommended that the water shut-off valve be placed in a location 
that is easily accessible. We do not advise placing it behind the unit 
because of access difficulties. If it is necessary to install the valve behind 
the unit, it must be located in the shaded area.
•  Saddle type shut-off valves are included in many water supply kits, but 
are not recommended for this application. 
•  The only GEA-approved plastic tubing is supplied in the SmartConnect
™
Refrigerator Tubing kits. Do not use any other plastic water supply line 
because the line is under pressure at all times. Other types of plastic may crack or rupture with age and cause water 
damage to your home. SmartConnect
™
 Refrigerator Tubing Kits are available in the following lengths: 
6’ (1.8 m) WX08X10006, 15’ (4.6 m) WX08X10015 & 25’ (7.6 m) WX08X10025
•  Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use 
is not permitted in Massachusetts. Consult with your licensed plumber.
Electrical Specifications
•  A 115-volt, 60-Hz., 15- or 20-amp power supply is required. An individual properly grounded branch circuit or circuit 
breaker is recommended. 
•  Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on 
rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
THE INSTALLATION SPACE
GROUNDING THE REFRIGERATOR
IMPORTANT—(Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST 
BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a 
3-prong (grounding) plug which mates with a standard 
three-prong (grounding) wall receptacle to minimize the 
possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified 
electrician to make sure the outlet is properly grounded.
Where a standard 2-prong wall outlet is encountered, it 
is your personal responsibility and obligation to have it 
replaced with a properly grounded 3-prong wall outlet.
DO NOT, UNDER ANY 
CIRCUMSTANCES, CUT  
OR REMOVE THE THIRD  
(GROUND) PRONG FROM  
THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE 
REFRIGERATOR TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS 
APPLIANCE.
6”
80”
77”
A
nti-Tip location. Do 
not obstruct this area.
Water and Electrical
Tube Outlet
Front view
Install Space