Specifications
Bx oven range inc condenser 05-06 (12-07) RAC
8
1. The oven should be connected to a wall isolator.
4.0 INSTALLATION
2. It is the customers’ sole responsibility to arrange adequate ventilation and it should be
sufficient to ensure water does not condense on or around the oven. A 50mm gap is
required at the sides and rear of this oven.
Chimneys and evacuation ducts, fitted above mono ovens should be insulated.
3. If an oven with steam has been chosen, connect to a suitable water supply making sure
that the pipes are flushed out to remove all foreign bodies i.e. flux or solder. Customers in
hard water areas must ensure that an efficient water treatment device protects the supply
to the oven. It is the customers’ responsibility to install and maintain an adequate water
supply to the oven.
4. In the interests of hygiene, we strongly recommend that before using the oven for the first
time you wipe the inside of the oven and all accessories thoroughly with a clean cloth
soaked in warm soapy water. Although the utmost care is taken during assembly and pre-
delivery inspection, there is always a possibility of residue contaminating the first bake if
this is not done.
5. Ensure that the locking castors on the base unit (if supplied) are locked into position.
6. AMBIENT WORKING TEMPERATURES.
Ambient working temperatures for electric/electronic components such as solenoid
switches, circuit breakers, motors etc should be no more than 40
q
C (115
q
f)
Manufacturers of these and other electrical components advise that any ambient temperature above 40
q
C
affects the functionality of the components and any related guarantees become void. For example, above thi
s
temperature motors are not satisfactorily cooled, contactor efficiency is seriously impaired and electronic
components shut down. It is the customers’ sole responsibility to arrange for adequate ventilation. Any
component malfunctioning during the guarantee period that is found to have been subject to excessive
humidity or ambient working temperature above 40
q
C (115
q
F) will not be covered by the component
manufacturers guarantee or MONO
’
s product warranty
.