User`s manual

GLOBAL SETTINGS
90
The available selections for all the parameters are:
INT - O
nly internal control, no external MIDI data will be sent.
OUT - No internal control, only external MIDI data will be sent.
INT+OUT - Internal control, and MIDI data will be sent.
Parameter locks of the internal tracks are not transmitted over MIDI, because the
data transfer rate of the MIDI standard is too low for delivering large number of
control data in time.
Note that if internal control is shut off the Monomachine might appear non-func-
t
ional if MIDI data is not echoed back from an external sequencer.
CONTROL OUT2
Here parameters dealing with how the Monomachine handles outgoing MIDI sequencer
control messages are found.
1. Select the CONTROL in the GLOBAL menu. Then select CONTROL OUT2 using the
[ARROW] keys and press [ENTER/YES].
TRANSPORT (transport) controls whether MIDI Start, Stop and Song Pointer Position are
sent.
MIDI CLOCK (MIDI clock) controls whether the Monomachine transmits MIDI clock.
PRG CHANGE (program change) controls whether MIDI PRG CHANGE is sent for each
pattern change.
CONTROL IN
In this menu it is defined how the Monomachine should react to incoming MIDI.
1. Select the CONTROL in the GLOBAL menu. Then select CO
NTROL IN using the
[ARROW] keys and press [ENTER/YES].
TEMPO SYNC (tempo sync) defines how the Monomachine should react to incoming MIDI
clock. When this parameter is set to EXTERNAL, the Monomachine tempo will be slaved to
incoming MIDI time clock. The precision of the timing is limited to the precision of the unit
transmitting the MIDI clock signal. When locked to external clock the BPM indicator on the