User`s guide
15
Min. and Max.
The Minimum and Maximum text fields specify the range of each
slider. To change the range, simply type a new number into the
Minimum or Maximum field.
Parameter Field
Each slider has a Parameter field (“Param.”), which lets you enter a
brief description of that slider’s function. It is helpful to include
units, such as %, ms, or Hz, when entering slider descriptions.
Preset Description Field
The Slider Screen also has a Preset Description field (“Preset Desc.”),
which allows you to enter any relevant information about the
current Preset, such as its purpose and how it works.
Clipping / Limiting Indicator
The Clipping / Limiting Indicator lights up to show that clipping
(signal distortion) or limiting have occurred.
If clipping or limiting occur, you may want to adjust the preset’s
“Output Volume” or other parameters that may be causing signal
overflow.
The Limiter can be controlled via the Limiter Setup preset in the
Limiter Category. Unlike all other presets, the Limiter Setup preset
affects ALL presets.