User`s guide

To set the Static IP, uncheck the Use DHCP box and ll in the settings:
The force transmit on Aware box tells the gateway to deliver immediately the messages
marked as Aware from the sensors. If this box is unchecked and the setting is saved,
then the gateway only dumps the sensor messages it has been collecting on the Heart-
beat Interval. This allows for controlled communication when sporadic communication
from the gateway is either unacceptable or not ideal.
2. External Interfaces:
Data collected by the Ethernet Gateway from the sensors in the network can be ac-
cessed when these interfaces are turned on. Multiple interfaces can be active at the
same time. All interfaces require that the Ethernet gateway be set to a Static IP ad-
dress. (By default, the unit uses DHCP).
Real Time TCP Interface
Poll on the gateway’s assigned port to retrieve gateway and sensor data.
Mark the interface active and Save. The default port is 3500, but can be edited.
PAGE 13