Specifications

SECTION
B
SPECIFICATIONS
Model
Monitor
2400
Fuel
Type
Crystal
Clear Kerosene
Heater
Efficiency
93%'
Heat Rating
High
:
43,000
BTU/hour
H.Medium
:
32,000 BTU/hour
L.Medium
:
24,600 BTU/hour
Low:
16,200
BTU/hour
Heater
Output
High
:
37,200 BTU/hour
H.Medium
:
26,900 BTU/hour
L.Medium
:
20,700
BTU/hour
Low
:
13,600
BTU/hour
Fuel
Tank
Fuel
Consumption
Separate
(Not supplied with heater)
High
:
0.319
Gallon/hour
H.Medium
:
0.24 Gallon/hour
L.Medium
:
0.18 Gallon/hour
Low
:
0.12 Gallon/hour
Power
Source
120
Volts
AC;
60
Hz.
Power
Consumption
Ignition
: 310
Watts
Operation
: 68
Watts (Average)
Heated
Air
Delivery
High:
388
Cubic feet/minute
H.Medium:
388
Cubic feet/minute
L.Medium:
330
Cubic
feet/minute
Low:
300
Cubic feet/minute
Vent
Pipe Hole
2/1>-inches
Diameter
Dimensions
Height:
26.6
inches
Width:
28.7 inches
Depth:
14.0 inches
Weight
82
Pounds, empty
* Net
Efficiency
is
88%,
A.F.U.E.is
84%
SPECIAL
FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP:
Set
memory
can be
kept
in
case
of
power
failure
for up to 30
minutes.
DUAL
BLOWERS:
Separate fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED:Adjusts
to the
desired
room temperature.
BUILT-IN
TIMER:Heater
will automatically operate
as
programmed
by the
user.
AUTOMATIC
RESET
AFTER
POWER
FAILURE:
Heater
will automatically resume operation after power
is
restored.
INDICATOR
LIGHTS
:
Easy-to-see signals show when
heater
is in
operation, when timer
is
activated,
and
when
the
burner
is
operating.
CHOICE
OF
FUEL
SUPPLY:Connect
to
separate
tank.
MULTIPLE
HEAT
EXCHANGER:Extracts
88% of
heat
from
burner.
CLEAN
OPERATION:
Products
of
combustion
are
vented
outside.
CONSUMES
NO
ROOM
AIR
:Airforcombustion
is
drawn
from
outside.
EASY
INSTALLATION:
Includes
all
parts required
for
standard
installation.
SAFETY
FEATURES
SAFE
RE-LIGHTING:Heater
will
not
restart
until
its
combustion chamber
has
cooled.
ELECTRICAL
PROTECTION:
Heater
automatically
shuts
off
in the
unlikely
event
of a
malfunction
in the
electrical
circuitry
or
disruption
of the
power supply.
NO
EXHAUST
IN
ROOM:
Products
of
combustion
are
discharged outdoors.
FLUE
PIPE:Outside
air is
drawn through
a
pipe-within-
a-pipe
venting system. This process preheats
combustion
air and
regains heat from exhaust
gases.
A
CAUTION-ALTERNATE
POWER
SOURCES
The
Monitor
2400
may not
operate
when
powered
by
sources
such
as an
auxiliary
generator,
UPS
(Uninterrupted
Power
Source),
inverters,
etc.
Check
with
your
dealer
for
guidance
on
specific
applications.