Specifications
SECTION
B
SPECIFICATIONS
Model Monitor 2200
Fuel Type
Red
dyed
or
Clear Kerosene
or Low
Sulphur
*1
Oil
Heater
Efficiency
93%*
Heat Rating
High:22,000
BTU/hour
H.Medium:
17,400
BTU/hour
L.Medium:
12,400
BTU/hour
Low:9,600
BTU/hour
Heater
Output
High:
18,260 BTU/hour
H.Medium:
14,440 BTU/hour
L.Medium:
10,290
BTU/hour
Low:7,970BTU/hour
Fuel Tank
Separate(Capsule tank optional)
Fuel Consumption
High:0.164
Gallon/hour
H.Medium:0.13
Gallon/hour
L.Medium:0.09
Gallon/hour
Low:0.07
Gallon/hour
Power
Source
120
Volts
AC;
60
Hz
Power
Consumption
Ignition:
250
Watts
Operational
Watts (Average)
Heated
Air
Delivery
High:
176
Cubic
feet/minute
H.Medium:
176
Cubic
feet/minute
L.Medium:
126
Cubic
feet/minute
Low:
113
Cubic
feet/minute
Vent
Pipe Hole
2>2-inches
Diameter
Dimensions
Weight
Height:26.0
inches
Width:20.9
inches
Depth:
13.0
inches
55
Pounds,empty
*
When
considering
heat
of
condensation
is
lost,
then
the net
efficiency
is
88%, A.F.U.E.
is 84%
SPECIAL FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP:Set
memory
can be
kept
in
case
of
power failure
for up to 30
minutes.
DUAL
BLOWERS:Separate
fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED
:
Adjusts
to the
desired room temperature.
BUILT-IN
TIMER:
Heater will automatically operate
as
programmed
by the
user.
AUTOMATIC
RESET AFTER POWER
FAILURE:Heater
will automatically resume operation after power
is
restored.
INDICATOR
LIGHTS:
Easy-to-see signals show when
heater
is in
operation, when timer
is
activated,
and
when
the
burner
is
operating.
CHOICE
OF
FUEL
SUPPLY:
Separate tank
or
Capsule
tank
optional.
MULTIPLE HEAT
EXCHANGER:
Extracts
88% of
heat
from
burner.
CLEAN
OPERATION:
Products
of
combustion
are
vented
outside.
CONSUMES
NO
ROOM
AIR:
Air for
combustion
is
drawn
from
outside.
EASY
INSTALLATION:
Includes
all
parts required
for
standard installation.
SAFETY FEATURES
SAFE
RE-LIGHTING:Heater
will
not
restart until
its
combustion chamber
has
cooled.
ELECTRICAL
PROTECTION:
Heater automatically shuts
off
in the
unlikely event
of a
malfunction
in the
electrical circuitry
or
disruption
of the
power supply.
NO
EXHAUST
IN
ROOM
:
Products
of
combustion
are
discharged outdoors.
FLUE
PIPE:
Outside
air is
drawn through
a
pipe-within-
a-pipe
venting system.
This
process preheats
combustion
air and
regains heat from exhaust
gases.
£±
CAUTION:ALTERNATE
POWER
SOURCES
The
Monitor 2200
may not
operate
when
powered
by
sources such
as an
auxiliary
generator,
UPS
(Uninterruptedpower
Source),
inverters,
etc.Check
with
your dealer
for
guidance
on
specific