Specifications
FLUE PIPE EXTENSIONS
Four
standard extension kits
are
available from your
Monitor dealer. Most
installations
can be
made
with
one
of
these
kits.
In
special cases, custom
installations
may
be
required. These
may be
made with components
purchased from your dealer.
In any
installation
the
following limitations MUST
NOT
BE
EXCEEDED:
1.
Trie
total
length
of the
intake
or
exhaust pipe should
not
exceed
10
feet
(3.05m)
with
3
elbows,
13
feet
(3.96m)
with
2
elbows,
or
16'/
2
feet
(5.3m)
with
1
elbow.
2.
These elbows should
include
the one
used
at the
heater
but not the one on the air
supply hose
nor the
integral
bends
in the
flue
pipe.
(See Figure
2)
3. The
correct damper
as
shown
on
Page
14
must
be
used.
4.
Follow carefully
the
instruction included with
each
kit.
Exhaust
Elbow
90°
Joint
Air
Supply Hose
Flue Pipe
Do
not
count
Fig.
2