Specifications
SECTION
B
SPECIFICATIONS
Model
No.
GF500
Type
of
Appliance
Fan
type direct vent wall furnace
Input Rating Nat.
Gas
38,000 BTU/hour
LP.
Gas
34,500 BTU/hour
Output Rating
Nat.
Gas
30,700 BTU/hour
LP. Gas
27,900 BTU/hour
Efficiency
83%
Electrical Rating
120V,
60Hz, Less than
2
amperes
Power
Consumption
80
Watts
Heated
Air
Delivery
High
388
Cubic
feet/minute
Low
300
Cubic
feet/minute
Flue Pipe Hole
2.5
inches diameter
Dimensions Height: 26.6 inches (67.56cm)
Width: 28.7 inches (72.90cm)
Depth: 13.8 inches (35.05cm)
Weight
82
pounds
Inlet
Gas
Supply Pressure Nat.
Gas
Max.
Min.
10.5
inch W.C. (267
mmH
2
O)
5.1
inch W.C.
(130mmH
2
O)
LP.
Gas
Max.
13.0
inch W.C. (330
mmH
2
O)
Min.
11.0
inch W.C. (279
mmH2O)
Manifold Test Pressure
Nat.
Gas 3.4
inch W.C.
(85
mmH
2
O)
LP.
Gas 3.4
inch W.C.
(86
mmH
2
O)
The
minimum
and
maximum inlet
gas
supply pressure
are for the
purpose
of
input adjustment.
The
efficiency rating
of
this appliance
is a
product
of
thermal efficiency rating determined under
continuous
operating conditions
and was
determined independently
of any
installed system.
SPECIAL
FEATURES
AUTOMATIC
IGNITION
MEMORY
BACK
UP: Set
memory
can be
kept
in
case
of
power failure
for up to 5
minutes.
DUAL BLOWERS: Separate fans
for
combustion
and
room
air
circulation.
THERMOSTATICALLY
CONTROLLED: Adjusts
to the
desired room temperature.
BUILT-IN
TIMER: Heater
will
automatically
operate
as
programmed
by the
user.
AUTOMATIC
RESET AFTER POWER FAILURE: Heater
will automatically resume
operation
after power
is
restored.
INDICATOR
LIGHTS: Easy-to-see
signals
show when
heater
is in
operation,
when timer
is
activated,
and
when
the
burner
is
operating
in low or
high
modes.
CLEAN
OPERATION:
Products
of
combustion
are
vented
outside.
CONSUMES
NO
ROOM AIR:
Air for
combustion
is
drawn
from outside.
EASY
INSTALLATION: Includes
all
parts
required
for
standard
installation.
SAFETY
FEATURES
SAFE
RE-LIGHTING: Heater
will
not
restart
until
its
combustion
chamber
has
cooled.
ELECTRICAL PROTECTION: Heater automatically shuts
off
in the
unlikely event
of a
malfunction
in the
electrical
circuitry
or
disruption
of the
power supply.
NO
EXHAUST
IN
ROOM: Products
of
combustion
are
discharged
outdoors.
FLUE
PIPE: Outside
air is
drawn through
a
pipe-within-
a-pipe
venting
system. This process preheats
combustion
air and
regains heat from exhaust gases.
A
CAUTION:
ALTERNATE POWER SOURCES
The
Monitor
GF500
may not
operate when powered
by
sources such
as an
auxiliary
generator,
UPS
(Uninterrupted
Power Source), inverters, etc.
Check
with
your dealer
for
guidance
on
specific
applications.