Specifications
FLUE
PIPE EXTENSIONS
Four
standard extension kits
are
available from your
Monitor dealer. Most installations
can be
made with
one
of
these
kits.
In
special
cases,
custom
installations
may
be
required. These
may be
made with components
purchased
from your dealer.
In
any
installation
the
following limitations MUST
NOT
BE
EXCEEDED:
2.
These elbows should include
the one
used
at the
heater
but not the one on the air
supply hose
nor the
integral
bends
in the
flue
pipe.
(See Figure
2)
3.
The
correct damper
as
shown
on
Page
13
must
be
used.
4.
Follow carefully
the
instruction included with each
kit.
1.
The
total length
of the
intake
or
exhaust pipe should
not
exceed
10
feet
(3.05m)
with
3
elbows,
13
feet
(3.96m)
with
2
elbows,
or
16
1
/2
feet
(5.3m)
with
1
elbow.
Exhaust
Elbow
90°
Joint
Air
Supply Hose
Flue Pipe
*
Do
not
count
Fig.
2