Technical data
40 FastIron Ethernet Switch Administration Guide
53-1002637-02
Basic port parameter configuration
2
Specifying a management port
The management port number is always 1. This example shows how to specify the management
port:
Brocade (config) # interface management 1
ICX 6610
Specifying a data port
The port address format is is stack unit/slot/port, where:
• stack unit—Specifies the stack unit ID. Range is from 1 to 8. If the device is not part of a stack,
the stack unit ID is 1.
• slot—Specifies the slot number. Can be 1 or 3.
• port—Specifies the port number in the slot. Range is from 1 to 24 (24-port models) or 1 to 48
(48-port models).
This example shows how to specify port 2 in slot 1 of a device that is not part of a stack:
Brocade (config) # interface ethernet 1/1/2
Specifying a stacking port
The port address format is is stack unit/slot/port, where:
• stack unit—Specifies the stack unit ID. Range is from 1 to 8.
• slot—Specifies the slot number. Stacking ports are in slot 2.
• port—Specifies the port number in the slot. Dedicated stacking ports are 1, 2, 6, and 7.
This example shows how to specify stacking port 2 in slot 2 of unit 3 in a stack:
Brocade (config) # interface ethernet 3/2/2
Specifying a management port
The management port number is always 1. This example shows how to specify the management
port:
Brocade (config) # interface management 1
FCX
Specifying a data port
The port address format is stack unit/slot/port, where:
• stack unit—Specifies the stack unit ID. Range is from 1 to 8. If the device is not part of a stack,
the stack unit ID is 1.
• slot—Specifies the slot number. Can be 1 or 3.
• port—Specifies the port number in the slot. Range is from 1 to 24 (24-port models) or 1 to 48
(48-port models).
This example shows how to specify port 2 in slot 1 of a device that is not part of a stack:
Brocade (config) # interface ethernet 1/1/2