40 FastIron Ethernet Switch Administration Guide
53-1002637-02
Basic port parameter configuration
2
Specifying a management port
The management port number is always 1. This example shows how to specify the management
port:
Brocade (config) # interface management 1
ICX 6610
Specifying a data port
The port address format is is stack unit/slot/port, where:
stack unit—Specifies the stack unit ID. Range is from 1 to 8. If the device is not part of a stack,
the stack unit ID is 1.
slot—Specifies the slot number. Can be 1 or 3.
port—Specifies the port number in the slot. Range is from 1 to 24 (24-port models) or 1 to 48
(48-port models).
This example shows how to specify port 2 in slot 1 of a device that is not part of a stack:
Brocade (config) # interface ethernet 1/1/2
Specifying a stacking port
The port address format is is stack unit/slot/port, where:
stack unit—Specifies the stack unit ID. Range is from 1 to 8.
slot—Specifies the slot number. Stacking ports are in slot 2.
port—Specifies the port number in the slot. Dedicated stacking ports are 1, 2, 6, and 7.
This example shows how to specify stacking port 2 in slot 2 of unit 3 in a stack:
Brocade (config) # interface ethernet 3/2/2
Specifying a management port
The management port number is always 1. This example shows how to specify the management
port:
Brocade (config) # interface management 1
FCX
Specifying a data port
The port address format is stack unit/slot/port, where:
stack unit—Specifies the stack unit ID. Range is from 1 to 8. If the device is not part of a stack,
the stack unit ID is 1.
slot—Specifies the slot number. Can be 1 or 3.
port—Specifies the port number in the slot. Range is from 1 to 24 (24-port models) or 1 to 48
(48-port models).
This example shows how to specify port 2 in slot 1 of a device that is not part of a stack: