Technical data

358 FastIron Ethernet Switch Administration Guide
53-1002637-02
Syslog messages
A
Informational telnet | SSH| access [by username] from src
IP source ip address, src MAC source MAC
address rejected, n attempts
There were failed SSH, or Telnet login
access attempts from the specified source
IP and MAC address.
[by user username] does not appear if
telnet or SSH clients are specified.
n is the number of times this SNMP
trap occurred in the last five minutes,
or other configured number of
minutes.
Informational Trunk group (ports) created by 802.3ad
link-aggregation module.
802.3ad link aggregation is configured on
the device, and the feature has dynamically
created a trunk group (aggregate link).
The ports variable is a list of the ports that
were aggregated to make the trunk group.
Informational user username added | deleted | modified
from console | telnet | ssh| snmp
A user created, modified, or deleted a local
user account through the SNMP, console,
SSH, or Telnet session.
Informational vlan vlan id added | deleted | modified from
console | telnet | ssh| snmp session
A user created, modified, or deleted a VLAN
through the SNMP, console, SSH, or Telnet
session.
Informational Warm start The system software (flash code) has been
reloaded.
Informational Stack: Stack unit unit# has been deleted to
the stack system
The specified unit has been deleted from
the stacking system.
Informational Stack unit unitNumber has been elected as
ACTIVE unit of the stack system
The specified unit in a stack has been
elected as the Master unit for the stacking
system.
Informational Stack: Stack unit unit# has been added to
the stack system
The specified unit has been added to the
stacking system.
Informational System: Management MAC address changed
to mac_address
The management MAC address of a
stacking system has been changed
Informational System: Stack unit unit# Fan fan#
(description), failed
The operational status of a fan in the
specified unit in a stack changed from
normal to failure.
Informational System: Stack unit unit# Power supply
power-supply# is down
The operational status of a power supply of
the specified unit in a stack changed from
normal to failure.
Informational System: Stack unit unit# Power supply
power-supply# is up
The operational status of a power supply of
the specified unit in a stack changed from
failure to normal.
Informational System: Stack unit unit# Fan fan#
(description), ok
The operational status of a fan in the
specified unit in a stack changed from
failure to normal.
Informational System: Stack unit unitNumber Temperature
actual-temp C degrees, warning level
warning-temp C degrees, shutdown level
shutdown-temp C degrees
The actual temperature reading for a unit in
a stack is above the warning temperature
threshold.
TABLE 1 Brocade Syslog messages (Continued)
Message level Message Explanation