Technical data
FastIron Ethernet Switch Administration Guide 349
53-1002637-02
Appendix
A
Syslog messages
Table 1 lists all of the Syslog messages. Note that some of the messages apply only to Layer 3
switches.
NOTE
This chapter does not list Syslog messages that can be displayed when a debug option is enabled.
The messages are listed by message level, in the following order, then by message type:
• Emergencies (none)
• Alerts
• Critical
• Errors
• Warnings
• Notifications
• Informational
• Debugging
TABLE 1 Brocade Syslog messages
Message level Message Explanation
Alert num-modules modules and 1 power supply,
need more power supply!!
Indicates that the chassis needs more
power supplies to run the modules in the
chassis.
The num-modules parameter indicates the
number of modules in the chassis.
Alert Fan num, location, failed A fan has failed.
The num is the fan number.
The location describes where the failed fan
is in the chassis.
Alert MAC Authentication failed for mac-address
on portnum
RADIUS authentication was successful for
the specified mac-address on the specified
portnum; however, the VLAN returned in the
RADIUS Access-Accept message did not
refer to a valid VLAN or VLAN ID on the
Brocade device. This is treated as an
authentication failure.
Alert MAC Authentication failed for mac-address
on portnum (Invalid User)
RADIUS authentication failed for the
specified mac-address on the specified
portnum because the MAC address sent to
the RADIUS server was not found in the
RADIUS server users database.