Technical data
342 FastIron Ethernet Switch Administration Guide
53-1002637-02
show sysmon counters
show sysmon counters
Displays sysmon counters for all or specific event types.
Syntax show sysmon counters type {error | link}
show sysmon counters {ecc-error | link-error}
Command
Default
All counters are displayed.
Parameters type The event type for which sysmon counters are displayed. For FSX devices, the
options are all, fa (fabric adapter), pp (packet processor), and xbar (cross
bar). For FCX and ICX devices, the options are ecc-error and link-error. The
default value is all.
error Displays the error counter for the specified event type.
link Displays the link error counters. You can specify either all or specific links.
ecc-error Displays the ECC error count on FCX and ICX devices. This option is not
supported on FSX devices.
stack-unit Specifies the stack unit on which errors to be displayed.
all Displays errors for all stack units.
link-error Displays the link error count on FCX and ICX devices. This option is not
supported on FSX devices.
stack-unit Specifies the stack unit on which errors to be displayed.
all Displays errors for all stack units.
Command
Modes
Privileged EXEC mode.
Global configuration mode.
Examples The following displays all fabric adaptor statistics on an FSX device:
Brocade# show sysmon counters fa link all
Sysmon FA HG.link error detected (number of times)
FA-link0 FA-link1 FA-link2 FA-link3
SLOT FA-dev Sync/FC(RX,TX) Sync/FC(RX,TX)Sync/FC(RX,TX)Sync/FC(RX,TX)
1 0 0/(0,0) 0/(0,0) 0/(0,0) 0/(0,0)
2 2 0/(0,0) 0/(0,0) 0/(0,0) 0/(0,0)
9 16 1751/(1750,1750) 0/(0,0) 0/(0,0) 0/(0,0)
9 17 0/(0,0) 0/(0,0) 0/(0,0) 0/(0,0)
The following example displays the error events that sysmon has recorded for the fabric adaptor 0.
Brocade# show sysmon counters fa error 0
Sysmon error detected on: SLOT 1, FA 0(number of times)
****PUMA Device 0 VOQUnit0 error detect
Set 0 EnQ Drop detect = 0
Set 1 EnQ Drop detect = 0
Set 2 EnQ Drop detect = 0
Set 3 EnQ Drop detect = 0