Technical data
FastIron Ethernet Switch Administration Guide 339
53-1002637-02
clear sysmon counters
clear sysmon counters
Clears sysmon counters for all or specific event types.
Syntax clear sysmon counters all
clear sysmon counters fa {error | link} {all | decimal}
clear sysmon counters pp error {all | decimal}
clear sysmon counters xbar {error | link} {all | decimal}
clear sysmon counters {ecc-error | link-error}
Parameters all Clears all sysmon counters.
fa Clears the fabric adaptor sysmon counters.
error Clears the fabric adaptor error counters. You can specify all or a fabric
adaptor, identified by the index.
link Clears the fabric adaptor sysmon counters for links. You can specify all or a
fabric adaptor identified by the index.
pp error Clears packet processor sysmon counters. You can specify all or a packet
processor identified by the index.
xbar Clears cross bar sysmon counters for cross bar. You can specify all or a cross
bar identified by the index.
error Clears the cross bar sysmon error counters. You can specify all or a cross bar
identified by the index.
link Clears the cross bar sysmon counters for links. You can specify all or a cross
bar identified by the index.
ecc-error Clears the ECC error count on FCX and ICX devices. This option is not
supported on FSX devices.
stack-unit Specifies the stack unit on which errors to be cleared.
all Specifies that all stack units are cleared of errors.
link-error Clears the link error count on FCX and ICX devices. This option is not
supported on FSX devices.
stack-unit Specifies the stack unit on which errors to be cleared.
all Specifies that all stack units are cleared of errors.
Command
Modes
Global configuration mode.
Usage
Guidelines
None.
Examples The following example clears the fabric adaptor sysmon counters.
Brocade(config)# clear sysmon counters fa error all