Technical data

FastIron Ethernet Switch Administration Guide 329
53-1002637-02
System monitoring for Fabric Adapters
System monitoring for Fabric Adapters
On FSX devices, system monitoring for fabric adaptors monitor errors such as the following:
End of Packet (EoP) or Start of Packet (SoP) errors
Cyclic Redundancy Check (CRC) errors
Packets dropped due to congestion
In addition to the error count, sysmon also checks for connectivity of FA links. This happens at the
interval defined by the sysmon-timer command generally or specifically for FA.
Use the following commands configure and display the status of system monitoring on fabric
adaptors:
sysmon fa error-count
sysmon fa link
show sysmon counters
show sysmon logs
show sysmon config