Instruction Manual
MicroShockDetector plus
- 4 -
1. I N T R O D U CT I O N
1.1 S C O P E O F D E L I V E R Y
Thank you
for having chosen the MONILOG
®
MicroShockDetector plus.
Scope of delivery
1
(standard):
• MONILOG
MicroShockDetector plus, incl. 1 replaceable lithium cell of type LR06 (AA,
Mignon) 3.6 V / 2500 mAh, lithium content ~ 0.7g
• USB stick
▪ Configuration software „MONILOG Analyzer“ with integrated software help
▪ Driver for USB interface
▪ Operating instruction in electronic form (PDF)
▪ Application examples, transport monitoring manual
• USB 2.0 interface cable (type A ↔ type Mini AB)
In order to be able to further optimise our products for the respective applications, we are always
open to suggestions and change requests on your part.
1) The scope of delivery can deviate from the standard due to special contract agreements!
1.2 B R I E F I N S T R U C T I O N S F O R T H E I N S T A L L E R
Assuming the MONILOG
MicroShockDetector plus is pre-programmed for the application and the
battery cell capacity sufficiently, the device only needs to be attached to the cargo and turned on.
The mounting is preferably with 2 mounting screws or optionally with magnetic bases (see Section
3.4).
Briefly (<3 sec) press the CONTROL-button. If the STATUS LED is green, the device is ready for
use and you do not have to do anything else. Otherwise, press the CONTROL-button for at least 3
seconds to switch on the device until STATUS LED light up in green and then release the button.
In all other states, the device can only be operated using the analyzer software MONILOG
®
(see
Section 3.2). If the STATUS LED lights up red, there is an error. Follow the instructions in the
MONILOG
®
analyzer or ask your administrator or the manufacturer.
To switch off the device, press the CONTROL-button for at least 5 seconds until the STATUS LED
lights up red.