20307670
CONNECTING THE GAS LINE
NOTICE: A qualifi ed gas appliance installer must connect 
the heater to the gas supply. Consult all local codes.
CONNECT GAS LINE
To Fireplace
Pipe Coupling
Stainless 
Flexible Tube
Pipe
Locations Pressure 
Tapping Point Instal-
lation
Manual Shutoff 
Valve
Gas Supply 
Inlet
Figure 15 - 
Gas Connection
IMPORTANT: Loosen the pipe adapter on the fl ex tube 
before installing to the system piping.
Always use an external regulator for all propane/LPG heat-
ers only, to reduce the supply tank pressure to a maximum 
of 13" w.c. This is in addition to the internal regulator in the 
heater valve.
To reach factory installed fl ex line, go through access door 
on right or left side of fi rebox. 
Figure 16 - 
Access Holes
The stainless fl ex line is on the right side facing the fi re-
place and can connect to either a 3/8 NPT female or 1/2 
NPT male pipe. To connect from the opposite side, route 
the pipe under the rear portion of the unit. 
Test all gas joints from the gas meter to the heater valve 
for leaks using a gas analyzer or soap and water solution 
after completing connection. DO NOT USE AN OPEN 
FLAME.
Check the gas pressure with the appliance burning and 
the control set to HIGH.
Open control access door on either side of unit to fi nd valve 
and regulator referred to below. Figure 16
Cord Protector 
Manual Gas Shutoff
(Recommended Outlet 
Positioned Vertical)
Stainless Flex Line
Access Door 
for Gas Line
WARNING: Connecting directly to an 
unregulated propane/LPG tank can 
cause an explosion
WARNING: Use new black iron or 
steel pipe. Internally tinned copper or 
copper tubing can be used per National 
Fuel Code, section 2.6.3, providing gas meets 
hydrogen sulfi de limits, and where permitted by 
local codes. Gas piping system must be sized to 
provide minimum inlet pressure (Listed on Data 
Plate) at the maximum fl ow rate (BTU/hr). Undue 
pressure loss will occur if the pipe is too small.
A manual shutoff valve must be installed 
upstream of the appliance. Union tee and 
plugged 1/8" NPT pressure tapping point should 
be installed upstream of the appliance. Figure 13
WARNING: CHECK GAS TYPE: The 
gas supply must be the same as stated 
on the heater’s rating plate. If the gas 
supply is different, DO NOT INSTALL THE 
HEATER. Contact your dealer for the correct 
model. Connecting to the wrong gas type may 