Owner's Manual
5
Hearth Dimensions and Firebox Locations
FIREBOX LOCATION
Carefully select the best location for installation of your
vent free rebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and windows.
See “Clearances/Height Requirements on page 12.
Minimum clearances to combustibles must be main-
tained.
• Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers for
forced air furnaces / air conditioners, windows or doors.
• Installation must provide adequate ventilation and com-
bustion air.
• Location should be out of high trafc or windy or drafty
areas.
• DO NOT INSTALL WHERE CURTAINS, FURNITURE,
CLOTHING OR OTHER FLAMMABLE OBJECTS ARE
LESS THAN 42" FROM FRONT OF HEATER.
• Never obstruct the front opening of the vent free rebox
or restrict the ow of combustion and ventilation air.
• Do not install in the vicinity where gasoline or other
ammable liquids may be stored. The vent free rebox
must be kept clear and free from these combustible
materials.
Figure 5.1 Minimum Hearth Dimensions
Ref. LSTF36-B
A 33½"
B 19"
C 27¾"
A
B
C
13
Monessen • LSTF36-B Installation and Operating Manual • 4613-900 • Rev B • 10/19