Owner's Manual
6
Clearances
Ensure that minimum clearances shown in Figures 6.1
through 6.3 are maintained. Left and right clearances are
determined when facing the front of the rebox.
Follow these instructions carefully to ensure safe instal-
lation. Failure to follow these requirements may create a
re hazard.
1. Sidewall clearances: The clearance from the inside
of the appliance to any combustible wall should not be
less than 9". See Figure 6.1.
2. Ceiling clearance: The ceiling must be at least 42"
from the top of the rebox opening. See Figure 6.1.
3. Back wall clearance: The appliance may be placed
against a combustible back wall.
9"
Minimum
42"
Minimum
9"
Minimum
FP2687
minimum clearances
FP2687
4. Mantel clearances: If a combustible mantel is installed,
it must meet the clearance requirements as shown in
Figures 6.2 & 6.3.
12”
10”
8”
6”
2¹⁄₂”
12”
16”
19”
21”
23”
FP2690
Mantel clearances
Combustible
Material Can
Contact Top
of Fireplace
FP2690
Noncombustible Material
Only if Needed to Cover
Radiant Top Face
45°
1”
2¹⁄₂”
3”
5”
6”
1¹⁄₂”
3¹⁄₂”
4¹⁄₂”
FP2692
mantel leg clearance
6”
7¹⁄₂”
7¹⁄₂”
9”
Finish Wall
Combustible
Material Area
FP2692
NOTE: The canopy supplied with the unit must be installed
for correct mantel clearances.
Figure 6.1 Clearance and Height Requirements
Figure 6.2 Mantel Clearances
Figure 6.3 Mantel Leg Clearance
11
Monessen • BUF36/42 Installation and Operating Manual • 4600-900 • Rev C • 05/17