User Guide
58D6002 9
CODES
Adheretoalllocalcodesor,intheirabsence,thelatesteditionofTHENATIONALFUELGASCODEANSIZ223.1or
NFPA54whichcanbeobtainedfrom…
American National Standards Institute, Inc.
1430Broadway
NewYork,NY10018
or
National Fire Protection Association, Inc.
BatterymarchPark
Quincy,MA02269
GENERAL INSTALLATION INFORMATION
ADEQUATE COMBUSTION AND VENTILATION AIR
Thisheatershall notbeinstalledina connedspaceorunusuallytight constructionunlessprovisionsareprovidedfor
adequate combustion and ventilation air.
The National Fuel Gas Code, (ANSI Z223.1/NFPA54),denesaconnedspaceasaspacewhosevolumeislessthan50
cubicfeetper1,000BTUperhour(4.8m
3
perkw)oftheaggregateinputratingofallappliancesinstalledinthatspaceand
anunconnedspaceasaspacewhosevolumeisnotlessthan50cubicfeetper1,000BTUperhour(4.8m
3
perkw)ofthe
aggregateinputratingofallappliancesinstalledinthatspace.Roomscommunicatingdirectlywiththespaceinwhichthe
appliancesareinstalled,throughopeningsnotfurnishedwithdoors,areconsideredapartoftheunconnedspace.
UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE…
a) wallsandceilingsexposedtotheoutsideatmospherehaveacontinuouswatervaporretarderwitharatingof1perm
(6x10
11
kgperpa-sec-m
2
)orlesswithopeningsgasketedorsealed;
b) weatherstrippinghasbeenaddedonopenablewindowsanddoors,and
c) caulkingorsealantsareappliedtoareassuchasjointsaroundwindowanddoorframes,betweensoleplatesandoors,
betweenwall-ceilingjoints,betweenwallpanels,atpenetrationsforplumbing,electrical,andgaslines,andatother
openings.
WARNING
Do not install the heater …
• Where curtains, furniture, clothing, or other flammable objects are less than 42" from
the front of the heater.
• In high traffic areas.
• In windy or drafty areas.