PRODUCT SPECIFICATIONS
Gas Rate
Model Number
DLY18NM, GLY18NM
DLY24/30NM, GLY24/30NM
DLY18NV, GLY18NV
DLY24/30NV, GLY24/30NV
Type
Manual
Manual
Milli-Volt
Mill-Volt
Natural Gas
Manual Millivolt Pressure
Regulator Pressure Setting: 4.0" w.c. Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c. Gas Inlet Pressure: Max. 10 1/2" w. c.
Min. 5" w.c. Min. 5" w.c.
Propane / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w. c.
Manual Millivolt Pressure
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c. Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c. Minimum 11" w.c.
Ignition - Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Controls
Manual control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN -Valve position to light/maintain a standing pilot.
HI/LOW -Variable position corresponding to desired flame height (heat output).
Millivolt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN -Valve position to light/maintain a standing pilot.
ON -Valve position to turn ON/OFF log set with remote switch/thermostat.
HI/LOW -Variable position corresponding to desired flame height (heat output).
Type
Manual
Manual
Milli-Volt
Mill-Volt
Gas Rate
Model Number
DLY18PM, GLY18PM
DLY24/30PM, GLY24/30PM
DLY18PV, GLY18PV
DLY24/30PV, GLY24/30PV
Min. BTU/Hr
17,000
20,000
17,000
28,000
Max. BTU/Hr
21,000
36,000
21,000
36,000
Max. BTU/Hr
24,000
36,000
24,000
36,000
Min. BTU/Hr
18,000
20,000
18,000
25,000