Operating instructions
13
CLEARANCES / HEIGHT REQUIREMENTS
Figure 6: Minimum Mantel Clearance
with Hood--All Models
Example: A mantel may project from the wall a maximum of
2 1/2" at a minimum of 13" above the opening, and a maxi-
mum of 10" at a minimum of 18" above the opening.
Figure 7: Minimum Mantel Clearance
with No Hood - DLY/GLY 24 & 30
Example: The bottom of the mantel may project from the
wall of a maximum of 10" at a minimum of 32" above the
opening.
2 1/2"
6"-10"
12"
13"
18"
20"
8"
Min.
Heat Resistant
Material
Heat Resistant
Material
10" or Less
32"
20"
Min.
2 1/2"
6"-8"
10"
15"
18.5"
20"
20"
Min.
Heat Resistant
Material
Figure 7a: Minimum Mantel Clearance
with No Hood - DLY/GLY 18
Example: A mantel may project from the wall a maximum of
2 1/2" at a minimum of 15" above the opening, and a maxi-
mum of 10" at a minimum of 20" above the opening.