Moisture Resistance
Thisoutdoorfireplacewillshedmoderateamountsof
water,butisnotwaterproof.Waterandcondensingwa-
tervapormayenterthechaseundercertainconditions.
Thefireplacewillnotperformasanexteriorwall.Mois-
turepenetrationmustbeconsideredforconstruction
thatplacesthefireplaceinstructurewallsoronmois-
turesensitivesurfaces.
Wheninstalledonexteriorwalls:MHSCrecommends
thefireplacechasebeconstructedoutsidethestruc-
ture'sweatherenvelope.Wheretheplatformmeets
thewall,useaflashingdetailsimilartothatrequired
forattacheddecks.Chaseplatforms,includinghearths
shouldslopeawayfromthestructureat1/4inperfoot.
Thefireplacecanbeshimmedlevel.
Wheninstalledonsurfaceswherewatermaycollector
causedamage:MHSCrecommendsaslopeof1/8in
to1/4inperfoottowardsthedrainportsuggested.The
fireplacecanbeshimmedlevel.
Hearthsshouldslopeawayfromthefrontofthefire-
placeandchaseat1/8into1/4inperfoot.Metalsafety
stripsmustbeontopofanycombustiblehearthmateri-
alsusedformoisturemanagement.
Clearance to Combustibles
Appliances
Top..........................................................0”(0mm)
Bottom.....................................................0”(0mm)
Side.........................................................0”(0mm)
Back........................................................0”(0mm)
PerpendicularSidewall...........................0”(0mm)
Topofunittoceiling..........................36”(914mm)
Frontofunittocombustibles.............36”(914mm)
Screened Porch Installation
TheODGRmaybeinstalledsafelyandisdesigncerti-
fiedbyCSAtobeinstalledinascreenedporchwith
theseguidelines:
Minimumporcharea..............................96sq.feet(9sqm)
Minimumcelingheight..................................... 92"(234cm)
Minimumoftwo(2)wallsmustbescreened
Minimumtopofscreenheight,sidewalls........6'6"(198cm)
Minimumscreenarea............................64sq.feet(6sqm)
Mantels
WARNING:A4"hoodmustbeusedifa
mantelistobeinstalled.
Theheightthatacombustiblemantelisfittedabovethe
fireplaceisdependentonthedepthofthemantel.This
alsoappliestothedistancebetweenthemantelleg(if
fitted)andthefireplace.
Forthecorrectmountingheightandwidthsreferto
Figures3aand3b
Noncombustiblemantelsandlegsmaybeinstalledat
anyheightandwidtharoundtheappliance.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be heat
resistant to prevent discoloration.
Ref. Mantel Ref. Mantel From Top
Shelf Depth of Comb. Chamber
Y 8" (203mm) A 28" (711mm)
Z 1¹⁄₂"(38mm) B 26" (660mm)
CFM146
TopofCombustion
Chamber
Fig. 3aMantelclearances.
Side View
Standoff
Maintainminimum
3/4"(19mm)
clearanceto
combustible.
Hearth
Ahearthisnotmandatorybutisrecommendedfor
aestheticpurposes.Werecommendanoncombustible