Operating instructions

83D0511
ILDV20/30/40 Fireplace Insert
5

This appliance has been certied for
use with either natural or propane gas.
Refer to the appropriate data plates.
This appliance is not for use with solid
fuels.
The appliance is approved for bed-
room or bedsitting room installa-
tions.
The appliance must be installed in
accordance with local codes if any. If
none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the
USA, CSA B149 in Canada.
This appliance is mobile home appr-
oved.
The appliance must be properly con-
nected to a venting system.
The appliance is not approved for
closet or recessed installations.

Piezo
Figure 1 -
ILDV Series Fireplace Insert
FP1919
ILDV parts
9/08
Blower
Blower Knob
ON/OFF
Switch
OFF/Pilot/ON
Knob
HI/LO Knob
Gas Shut-
Off Valve

Input ratings are shown in BTU per hour and are certied
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).

Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.
  
    
ILDV0NV Nat. 0,000 13,000 #44
ILDV0PV LP 0,000 16,000 1.35 mm
ILDV30NV Nat. 30,000 0,500 #37
ILDV30PV LP 30,000 3,000 #51
ILDV40NV Nat. 39,000 7,000 #31
ILDV40PV LP 38,000 30,000 #49

 The ILDV Series replace inserts work without
any electrical supply. The blower must be attached to
110/10V AC.