Operating instructions

83D0511
ILDV20/30/40 Fireplace Insert
31
Make sure the gas valve knob is in the “OFF” position. Wait at least ve (5) minutes before
start-ing maintenance.

A qualied agency should examine the venting system annually.

Clean the ceramic glass periodically. Condensation will sometimes form on the glass during a
cold startup. This is normal for all gas replaces and inserts. This condensation often attracts
dust and lint to the surface of the glass. The initial paint curing of the appliance can also leave
a slight lm on the glass. This is a temporary problem.
You should clean the glass after the rst two weeks of use. After that, you should clean the
glass no more than two or three times a season. Use a mild glass cleaner to clean the door.
Do not use abrasive cleaners. They will damage the glass surface.

Visually check pilot and burner ames periodically. Refer to Figure 36 for typical burner ame.
Refer to Figure 37 for typical pilot ame.

LG535
ILDV log flame
9/08
Figure 36 -
Typical Burner Flame
LG535
FP1943
pilot flame
Thermocouple
Thermopile
FP1943
Figure 37 -
Typical Pilot Flame