Operating instructions

83D0511
ILDV20/30/40 Fireplace Insert
19


A remote wall switch and up to fteen (15) feet of 18 Ga. wire may be used with this appliance. At-
tach the wall switch in a junction box at the desired location on the wall. Figure 14.
 



This insert will work without any electrical supply. Electricity is only needed to operate blower.
Verify proper operation after servicing.




National Electrical Code
ANSI/NFPA 70 (latest edition)Canadian Electrical Code, CSA C22.1



PILOT HI
LO
ON
OFF
FP1933
wall switch wiring
Figure 14 -
Wiring Diagram for Wall Switch
Sparker
Thermocouple
Piezo Igniter
Thermopile
Pilot Assembly
Switch
Millivolt
Valve
TH
TP
TH/TP
ON OFF
Optional 15'
Wall Switch
Optional
Remote Control
ON
OFF
ON
OFF

The remote control receiver may be installed in the control panel by removing
the ON/OFF switch and the knock-out plate. Slide the receiver into the space
where the knock-out plate was removed. Refer to remote instructions for wiring
and operation.
FP2177
remote receiver
Figure 15 -
Remote Receiver
FP177
Remote
Receiver
