Operating instructions
18
83D0511
ILDV20/30/40 Fireplace Insert
1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If
the gas supply is different from the replace, STOP! Do not install the appliance. Contact your
dealer immediately.
. Install and attach ex line provided with on this appliance to 1/" gas line.
3. After completing gas line connection, purge air from gas line and test all gas joints from the
gas meter to the replace for leaks. Use a soap and water solution or a gas sniffer.
4. To adjust ame height, turn HI/LO knob to HI to
get maximum pressure to burner. Turn HI/LO
knob to LO to get minimum pressure.
5. To check gas pressures at valve, turn captured
screw counter clockwise or 3 turns and then
place tubing to pressure gauge over test point.
Turn unit to high. Figure 13. After taking pressure
reading, be sure and turn captured screw clock-
wise rmly to reseal. Do not over torque. Check
test points for gas leaks with a soap and water
solution or an electronic gas leak detector.
FP1932
valve regulator with knobs
Pressure
Test "IN"
Pressure Test
"OUT"
HI/LO Knob
Pilot Adjustment Screw
FP193
Figure 13 -
Gas Pressure Check at Gas Valve