ILDV20/30/40 Fireplace Insert

1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If
the gas supply is different from the replace, STOP! Do not install the appliance. Contact your
dealer immediately.
. Install and attach ex line provided with on this appliance to 1/" gas line.
3. After completing gas line connection, purge air from gas line and test all gas joints from the
gas meter to the replace for leaks. Use a soap and water solution or a gas sniffer.
4. To adjust ame height, turn HI/LO knob to HI to
get maximum pressure to burner. Turn HI/LO
knob to LO to get minimum pressure.
5. To check gas pressures at valve, turn captured
screw counter clockwise or 3 turns and then
place tubing to pressure gauge over test point.
Turn unit to high. Figure 13. After taking pressure
reading, be sure and turn captured screw clock-
wise rmly to reseal. Do not over torque. Check
test points for gas leaks with a soap and water
solution or an electronic gas leak detector.
FP1932
valve regulator with knobs
Pressure
Test "IN"
Pressure Test
"OUT"
HI/LO Knob
Pilot Adjustment Screw
FP193
Figure 13 -
Gas Pressure Check at Gas Valve


