Operating instructions

1
83D0511
ILDV20/30/40 Fireplace Insert


The exhaust vent must reline the entire length of chimney and terminate above chimney top.
Vent must meet all vent manufacturer's requirements when installed.
Make sure you have the following before installing unit:
3" and 3" UL 1777 Listed gas liner for air inlet and exhaust.
Vertical Terminations kits:
 HEDV3T81, HEDV3T11, HEDVRT, AI31TK33A
 HEDV3T81, HEDV3T11, HEDVRT
Figure 6
Venting Unit
FP1922
vent requirements
9/08
Maximum Height 40'
(1.9 m)
Minimum Height 10'
(3 m)
Exhaust
Inlet
FP19
 
Figure 6
 

