Operating instructions
20304164
ICFDV Fireplace Insert
9
•
The insert must be placed within a code-conforming
masonry replace or a tested and listed zero-clear-
ance (UL-127, solid fuel) replace. Repair any replace
damage prior to installation.
• Because the insert uses a circulation blower, clean the
replace, smoke shelf and chimney before installing.
• This heater may be placed in a bedroom. Please be
aware of the large amount of heat this appliance pro-
duces when determining a location.
Figure 4 -
Minimum Openings
f p 2945
FIR E B O X DIM S
23”
( 584 m m )
21”
( 533 m m )
17”
( 432 m m )
30”
( 762 m m )
• The damper and grate must be removed.
•
The smoke shelf, internal bafes, screen, refractory and
metal or glass doors may be removed (if applicable)
.
• Do not remove or alter the insulation or any structured
rigid frame members (metal sides, oor, door frames,
face of the replace, etc.).
Please review the following carefully.
It is normal for inserts fabricated of steel to give off some
expansion and/or contraction noises during the start up or
cool down cycle. Similar noises are found with your furnace
heat exchanger or car engine.
It is not unusual for your insert to give off some odor the
rst time it is burned. This is due to the curing of the paint
and any undetected oil from the manufacturing process.
Burn your insert for at least six (6) hours on "HIGH" the
rst time you use it. Place the fan in the "OFF" position
during this time.
&P
ZEROCLEARANCEREQUIREMENTS
Insulation
Damper
Smoke
Shelf
Masonry Lining or Refractory
Screen
Metal or Glass Doors
Internal
Bafes
Masonry Lining or Refractory
Grate
Figure 5 -
Metal Fireplace Zero-Clearance Requirements