Operating instructions

20304164
ICFDV Fireplace Insert
5

This appliance has been certied for use
with either natural or propane gas. Refer
to the appropriate data plates.
This appliance is not for use with solid
fuels.
The appliance is approved for bedroom or
bedsitting room installations.
The appliance must be installed in accor-
dance with local codes if any. If none exist
use the current installation code. ANSI
Z223.1/NFPA 54 in the USA, CSA B149
in Canada.
This appliance is mobile home appr-
oved.
The appliance must be properly connected
to a venting system.
The appliance is not approved for closet
or recessed installations.


Input ratings are shown in BTU per hour and are certied
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).

Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.
  
    
ICFDV30LNTSC Nat. 31,000 22,500 #36

FP2946
ICFDV insert controls
Figure 1 -
ICFDV Series Fireplace Insert Controls
Control Board
AC Module
Gas
Valve
Command
Center
FP2946