Operating instructions
10
20304164
ICFDV Fireplace Insert
Consult local building codes before beginning the installa-
tion. The installer must make sure to select the proper vent
system for installation. Before installing vent kit, the installer
must read this insert manual and vent kit instructions.
Only a qualied installer/service person should install vent-
ing system. The installer must follow these safety rules:
• Wear gloves and safety glasses for protection.
• Use extreme caution when using ladders or when
on rooftops.
• Be aware of electrical wiring locations in walls and
ceiling.
The following actions will void the warranty on your vent-
ing system:
• Installation of any damaged venting component.
• Unauthorized modication of the venting system.
• Installation of any component part not manufactured
or approved by MHSC.
• Installation other than permitted by these instruc-
tions.
• The exhaust vent must reline the entire length of chim-
ney and terminate above chimney top.
• Vent must meet all vent manufacturer's requirements
when installed.
• Make sure you have the following before installing
unit:
• 3" and 3" UL 1777 Listed gas liner for air inlet and
exhaust.
• Vertical Terminations kits:
HEDV32T812, HEDV32T1212, HEDVRT,
A131AK33A
Figure 6 -
Venting Unit
FP2947
vent requirements
Maximum Height 40'
(12.9 m)
Minimum Height 10'
(3 m)
Exhaust
Inlet
FP2947
Figure 6