Woodburning Peninsula Fireplace Model: 624WBPF Installation, Operation and Maintenance Manual for Residential Installation Safety Notice: If this appliance is not properly installed, operated and maintained, a 539042 house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to MPL cover follow instructions may result in property damage, bodily injury or even death.
624WBPF Woodburning Fireplace CONTENTS Congratulations! You have chosen the finest wood burning fireplace available. Your fireplace has been designed for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace. Table of Contents Listing and Code Approvals................................................................................................. 2 Important Information...........................................................
IMPORTANT INFORMATION 624WBPF Woodburning Fireplace 1. Read these instructions entirely before beginning any part of the installation. Save these instructions for any future repairs. 2. Use these instructions as a guide during the installation of the fireplace. 3. Be sure these instructions become the property of and are reviewed by all future users of this fireplace to encourage proper operation and maintenance. 4.
624WBPF Woodburning Fireplace OPERATION GUIDELINES When an AK4 combustion air assembly and a combustion air duct are attached to the connecting point on the left or right side of the fireplace, combustion air may enter the firebox through a dampered opening behind the left or right side brick. This feature is designed for your benefit to reduce the room air used for combustion and to prevent excessive loss of heat from the room. When the fireplace is in use, this damper should be open.
624WBPF Woodburning Fireplace FIREPLACE DIMENSIONS 9” (229 mm) Gas Line Entrance (Bottom of Fireplace) 22 6M” (578 mm) 23” (584 mm) 12” (305 mm) 3656O” (927 mm) 1/2” (13 mm) 1/2” (13 mm) 42” (1067 mm) 45 6M” 3756M” (1162 mm) (946 mm) 3056M” (768 mm) 14(6 ” (378 mm) 856O” (216 mm) 12” (305 mm) 36” (914 mm) 38” (965 mm) 24” (610 mm) Figure 1 539042 MPL dims 53D9052
24WBPF Woodburning Fireplace This fireplace does not require any special foundation. If the fireplace is to be trimmed with large stone or brick facing, an adequate foundation is required to support these materials. Refer to Figures 1-5 as guides for selecting a location and determining the space required for the fireplace. CAUTION FIREPLACE LOCATION Do not install fireplace over carpeting.
624WBPF Woodburning Fireplace CLEARANCES Figure 3 Residential Installation (Flue Outlet Height) Chimney Cap Storm Collar Roof Flashing 14 ft. = Min. Height (No offsets) 14 ft. = Min. Height (2 30° Elbows) 21 ft. = Min. Height (4 30° Elbows) 86 ft. = Max. Height (Chimney support every 35 ft.) Firestop 11CF1 (1 ft. pipe) 11CF18 (1Z\x ft. pipe) 11CF3 (3 ft. pipe) 11CF4 (4 ft. pipe) Maintain 2” Minimum Air Space Between Chimney and Combustibles Firestop (Requires 17 x 17 framing) 1/2” Min.
624WBPF Woodburning Fireplace INSTALLATION PREPARATION Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above the roof of a single story wing of a two story building. Figure 6.
624WBPF Woodburning Fireplace FLOOR PROTECTION If this fireplace is installed on a combustible floor, the floor area 16 inches in front of, and 8 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension. Figures 6 & 7 With either type hearth extension minor shifting of the supporting floor or expansion and contraction may eventually cause a crack to develop between the hearth extension and the face of the fireplace.
624WBPF Woodburning Fireplace FIREPLACE COMPONENTS WH36 Glass Doors (Standard) Chimney Support 11CS 30° Elbow Set 11CF30-2 MPL Penisula Fireplace Hearth Extension Kit H1652 Firestop Spacer FS2A, FS6A AK4 Combustion Air Assembly (AK6 for Manufactured Home Installation) Flashing 8-6-12, 8-12-12 Extended Chimney Cap RLTCF11L Chimney Cap RLTCF11 SLTCF11 Chimney Sections 11CF4 11CF3 11CF18 11CF1 Flat Flashing 36"x72" (13.
624WBPF Woodburning Fireplace FIREPLACE INSTALLATION Location Selection Unpack and check the fireplace and chimney for damage. If any items have been damaged, report this to your dealer. Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to replacement parts page for proper identification of parts. Do not substitute parts. Use only parts listed for use with the Model 624WBPF fireplace. Fireplace Installation 1.
624WBPF Woodburning Fireplace CHIMNEY INSTALLATION Firestop Spacer Installation at Attic Level C L Inlet Air Pipe Figure 12 Figure 10 Flue Pipe Ceiling Joist 17” Min. (432 mm) 1856O” (470 mm) Firestop Spacer Header Chimney Section Firestop Spacer Installation at Floor Levels Inlet Air Pipe Flue Pipe Floor Joist 23” (584 mm) 22 6 ” (575 mm) 46” (1168 mm) 3/16” (5 mm) 38” (965 mm) 3” Min.
624WBPF Woodburning Fireplace CHIMNEY INSTALLATION 1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass through. Unless the chimney is to be offset, the point where the center line of the chimney will pass through the ceiling and roof can be determined with a plumb line as shown in Figure 10. The fireplace should be located in the planned installation position.
624WBPF Woodburning Fireplace CHIMNEY OFFSET INSTALLATION Offset Installation Sequence 1. Determine the location and amount of offset required, then select the combinations of chimney sections and elbows required from the offset chart. Refer to Page 15. 2. Install the first elbow by placing the extended flue into the mating part of the fireplace or chimney section. Push down until the outside or inlet air duct of the elbow overlaps and the snaps lock the elbow into the fireplace or chimney section. 3.
624WBPF Woodburning Fireplace CHIMNEY OFFSET INSTALLATION Chimney Requirements - Offset Installations Offset Chimney Flue Exit Rise Chimney Section FP282 B A 30° Elbow OffsetsIWF282 30° Return Elbow G 1' 1¹⁄₂' 3' 4' G D E 6 FT. 30° Offset Elbow Rise C 30° Return Elbow H Offset 30° Offset Elbow B 11CS Support H Hearth Floor Example 1 Example 2 Notes: G + H cannot exceed 20 feet. *11CF Chimney airspace clearance = 2" minimum.
624WBPF Woodburning Fireplace CHIMNEY CAP INSTALLATION NOTE: The proper height as previously explained is important to assure proper draft and safety. The chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney. The chimney should not be extended more than 90 inches above the supporting roof structure without additional support.
624WBPF Woodburning Fireplace CHIMNEY CAP INSTALLATION 1. Extend the regular chimney sections until the top of the chimney is 4” below the total flue height desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is completed. 2. Remove the shingles from around the chimney so that the flashing may be installed, with the upper part of the flashing under the shingles. 3. Set the flashing on the roof.
624WBPF Woodburning Fireplace OUTSIDE COMBUSTION AIR Outside Combustion Air Recommendations (continued) 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through the duct. Refer to Figures 3 and 25 for methods of installing the outside air for combustion assemblies. 2.
624WBPF Woodburning Fireplace OUTSIDE COMBUSTION AIR Installing Model 403 Duct Connector 1. 2. 3. 4. Push insulation back approximately 2” from the end of each duct. Slip each duct over duct connector until an equal length of connector extends into each duct. Place duck clamp over the end of each duct. Tighten duct clamp down snuggly. Push insulation back into place and over duct clamp. Figure 23 Figure 24 2“ App.
624WBPF Woodburning Fireplace GAS APPLIANCE INSTALLATION WARNING: Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling which can cause serious injury or death to its inhabitants. To reduce these risks to a minimum, the following important notices and instructions should be read and followed carefully. IMPORTANT NOTICES: 1.
624WBPF Woodburning Fireplace GAS APPLIANCE Figure 26 Gas Line Plumbing Detail Side Brick Outer Fireplace Wrap 4” Inner Fireplace Wrap Side Brick 24” Max. Fireplace Firebox Hearth Brick Gas Line Access Tube FP2356 Knockout Maintain 1/2” Minimum Air Space Clearance to Combustibles for Gas Line Out to 4” From Side of the Fireplace Combustible Materials May Be Located at Zero Clearance to Gas Line Beyond 4” From Fireplace Side.
624WBPF Woodburning Fireplace TRIM INSTALLATION DECORATIVE TRIM INSTALLATION Do not allow the trim materials to extend closer than 3/8 inch to the vertical edges of the firebox opening if you plan to equip the fireplace with glass doors. The face of the fireplace may be left exposed or trimmed with any noncombustible material such as brick, stone or marble. If a trim is installed, be sure it is fastened snugly to the face of the fireplace.
FIREPLACE OPERATION 624WBPF Woodburning Fireplace WARNING: If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open position. (See additional operation information in section titled “Operation Guidelines”.) Advantages of a Wood Burning Fireplace These are the practical, ecological advantages of wood as a fuel. Also to be considered is the aesthetic appeal. Most of us consider a wood fire with nostalgia.
624WBPF Woodburning Fireplace FIREPLACE OPERATION You’ll need a minimum of three logs, preferably four, to make a good fire. Add kindling and new logs as needed to rekindle a dying fire. New logs should be added at the rear grate after raking the coals toward the front. DO NOT OVERFIRE THE FIREPLACE. Overfire conditions may be created by large amounts of kindling, building scraps, or other improper fuels.
MAINTENANCE & SAFETY 624WBPF Woodburning Fireplace Fuel Storage Wood can be dried sufficiently for burning within a few weeks if protected form rain in a low humidity area. It is far better to cut wood and allow it to dry for a year. In all cases, the wood should be stacked so that both ends of the sticks are exposed to the air and protected from rain. The drier the wood, the more usable heat produced by the fire and less likely rapid accumulation of soot and creosote within the chimney is to occur.
624WBPF Woodburning Fireplace MAINTENANCE & SAFETY Fireplace Maintenance At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should be removed and the hearth area should be swept as clean as is practical. The slow absorption of moisture into the ashes over a long period of time could cause a condition which would be corrosive to the metal fireplace parts.
MAINTENANCE & SAFETY 624WBPF Woodburning Fireplace DONT’S 1. Don’t allow other installations or operation considerations to take priority over safety considerations. 2. Don’t attempt to use the fireplace until the installation is complete. 3. Don’t use unlisted parts and accessories with the fireplace except for special flashings that may be fabricated locally. 4. Don’t use damaged parts or accessories with this fireplace. 5. Don’t install the fireplace in an exposed or uninsulated area. 6.
624WBPF Woodburning Fireplace REPLACEMENT PARTS 1 2 7a,b,c 5 11 13a,b,c 12 6 4 10 8 3 1 Ref. Description Qty. 1. Panel, Front Ptd. Assy. 4 2. Panel, End Ptd.Assy. 1 539042 MPL 3. Panel, End Vented Ptd. Assy. 1 parts 4. Post, Corner Ptd. Assy. 4 5. Cap,Corner Post 2 6. Flange, Nailing Ptd. Assy. 2 7a. Panel, Firescreen w/Pull 4 7b. Rod, Curtain Rod 4 7c. Clip, Screen Rod 2 8. Grate Assy. Ptd. 1 9. Ledge, Hearth Front Assy. 4 10. Ledge, Hearth End Assy. 1 11. Firebrick, End/Base Assy. 2 12.
624WBPF Woodburning Fireplace 53D9052 29
624WBPF Woodburning Fireplace 30 53D9052
624WBPF Woodburning Fireplace LIMITED WARRANTY FACTORY-BUILT FIREPLACE AND COMPONENTS (except blowers) What is Covered and For How Long • Five-Year Coverage - For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com APRIL 2009 53D9042 • Rev.