Operating instructions

28
42D0200
Designer Series Gas Fireplaces

A remote wall switch and up to fteen (15) feet of 18 Ga. wire may be used with this appliance. Attach
the wall switch in a junction box at the desired location on the wall. Figure 39. Do not extend beyond
the wall switch wire length provided.
 Extended lengths of wire may cause the replace not to function properly. Longer length of wire
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.
Figure 39 -
Wiring Diagram for Wall Switch




PILOT HI
LO
ON
OFF
FP2919
DV wiring diagram
Piezo
Ignitor
Thermocouple
Sparker
Thermopile
Pilot
Assembly
Switch
ON
OFF
Millivolt
Valve
ON
OFF
Optional 15’
Wall Switch
FP2919