Designer Series Gas Fireplaces
4. Apply a bead of non-hardening mastic around the outside
edge of vent cap. Position the vent cap in the center of
hole on the exterior wall with the word “UP” on the vent cap
facing up. Insure proper clearance of 1" to combustibles
is maintained. Attach the vent cap with four wood screws
supplied. Figure 20
Replace the wood screws with appropriate fasteners
for stucco, brick, concrete, or other types of siding.
For vinyl siding, stucco, or wood exterior use vinyl siding
standoffs between vent cap and exterior wall. The vinyl siding
standoff prevents excessive heat from melting the vinyl siding
material. Bolt the vent cap to the standoff. Apply non-harden-
ing mastic around outside edge of the standoff instead of the
vent cap assembly. Use wood screws provided to attach the
standoff. Figure 21
5. Slide re stop over the vent pipe before connecting hori-
zontal run to vent cap. Figure 22
6. Insert vent pipe into the horizontal termination. The pipe
overlap should be a minimum of 1Z\v". Fasten all vent con-
nections with screws provided.
7. Slide re stop against the interior wall surface and
attach with screws. Figure 22
(continued)
HOT
FP1956
vinyl siding standoff
Figure 21 -
Installing Vinyl Siding Standoff
Apply
Mastic to All
Four Sides
Cut Vinyl Siding Away
to Fit Standoff
Wood Screw
Vent Cap
Bolt
Nut
Standoff
Deecting
Shield
HOT
FP1955
horizontal vent cap
Figure 20 -
Installing Horizontal Vent Cap
Vent Cap
Wood Screw
Apply Mastic to
All Four Sides
Deecting
Shield
FP1955
FP1956
FP1957
install firestop
Figure 22 -
Connecting Vent Cap with Horizontal Vent Pipe
Interior Wall
Surface
Horizontal
Vent Pipe
Screw
Vent Cap
(Horizontal
Termination)