Operating instructions
12
42D0200
Designer Series Gas Fireplaces
The appliance is shipped as a rear vent unit. If the installa-
tion layout requires the unit to be a top vent conguration
the appliance can be converted by following the steps
below.
When removing and retting the plates and adapter be
sure the associated gaskets are undamaged and retted
as required.
B\,
FP1991
remove screws
Screws
Flue Pipe
Adapter
Flue Pipe
Adapter
FP1991
Figure 10 -
Remove 16 Screws from Flue Pipe
Adapter and Flue Pipe Cover
FP1992
remove flue pipe
Screws
Flue Pipe
FP1992
Figure 11 -
Remove Flue Pipe
Flue Pipe
Cover
FP1993
replace flue pipe
Screws
Flue Pipe
FP1993
Figure 12 -
Attach Flue Pipe to Top Vent Coln-
guration
1. Remove the eight (8) screws securing the ue pipe
adapter to the replace body. Figure 10
2. Set the ue pipe adapter aside, complete with the
gasket. Do not damage the gaskets as the adapter and
gasket must be retted.
3. Remove the eight (8) screws securing the ue pipe cover
to the top of the intake box and remove the cover and
gasket. Figure 10
4. Remove eight (8) screws securing the ue pipe to the
back of the intake box and remove the pipe and gasket.
Figure 11
5. Replace ue pipe to top of rebox. Ensure the gasket is
in place and undamaged. Secure with eight (8) screws.
Figure 12
6. Place the ue pipe cover and gasket removed in step
3 over the ue opening in bottom of the intake box.
7. Ret the ue pipe adapter and gasket to the top of re-
place. Secure the adapter with eight (8) screws removed
in step 1.